Schneider Electric PowerChute™ Serial Shutdown güvenlik açıkları (CVE)

Schneider Electric PowerChute™ Serial Shutdown için yayımlanan CVE kayıtları, en yenisi üstte. Yeni bir açık çıktığında e-posta almak için takip edin.

11 sonuç
6.9Orta
CVE-2026-13348
Schneider Electric PowerChute™ Serial Shutdown

CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to a user account by performing an arbitrary number of authentication attempts when redirect handling is disabled.

2.4Düşük
CVE-2026-2401
Schneider Electric PowerChute™ Serial Shutdown

CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause confidential information to be exposed when a Web Admin user executes a malicious file provided by an attacker.

5.3Orta
CVE-2026-2400
Schneider Electric PowerChute™ Serial Shutdown

CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability exists that could cause application user credentials to reset when a Web Admin user alters the POST /setPCBEDesc request payload.

5.3Orta
CVE-2026-2403
Schneider Electric PowerChute™ Serial Shutdown

CWE-1284 Improper Validation of Specified Quantity in Input vulnerability exists that could cause Event and Data Log truncation impacting log integrity when a Web Admin user alters the POST /logsettings request payload.

5.3Orta
CVE-2026-2405
Schneider Electric PowerChute™ Serial Shutdown

CWE-400 Uncontrolled Resource Consumption vulnerability exists that could cause excessive troubleshooting zip file creation and denial of service when a Web Admin user floods the system with POST /helpabout requests.

6.9Orta
CVE-2026-2402
Schneider Electric PowerChute™ Serial Shutdown

CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on a sequence of req…

6.9Orta
CVE-2026-2404
Schneider Electric PowerChute™ Serial Shutdown

CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check request payload.

6.9Orta
CVE-2026-2399
Schneider Electric PowerChute™ Serial Shutdown

CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep request payload.

7.3Yüksek
CVE-2025-11567
Schneider Electric PowerChute™ Serial Shutdown

CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.

6.9Orta
CVE-2025-11566
Schneider Electric PowerChute™ Serial Shutdown

CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credential…

7.3Yüksek
CVE-2025-11565
Schneider Electric PowerChute™ Serial Shutdown

CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause elevated system access when a Web Admin user on the local network tampers with the POST /REST/UpdateJRE request payload.