Schneider Electric Modicon Controllers M241/M251 güvenlik açıkları (CVE)

Schneider Electric Modicon Controllers M241/M251 için yayımlanan CVE kayıtları, en yenisi üstte. Yeni bir açık çıktığında e-posta almak için takip edin.

8 sonuç
5.1Orta
CVE-2025-13902
Schneider Electric Modicon Controllers M241/M251; Schneider Electric Modicon Controllers M258/LMC058

CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a malici…

5.4Orta
CVE-2025-3117
Schneider Electric Modicon Controllers M241/M251; Schneider Electric Modicon Controllers M262

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists impacting configuration file paths that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data i…

6.5Orta
CVE-2025-3116
Schneider Electric Modicon Controllers M241/M251; Schneider Electric Modicon Controllers M258 / LMC058

CWE-20: Improper Input Validation vulnerability exists that could cause Denial of Service when an authenticated malicious user sends special malformed HTTPS request containing improper formatted body data to the controller.

5.4Orta
CVE-2025-3905
Schneider Electric Modicon Controllers M241/M251; Schneider Electric Modicon Controllers M258 / LMC058

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists impacting PLC system variables that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a …

6.5Orta
CVE-2025-3112
Schneider Electric Modicon Controllers M241/M251

CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause Denial of Service when an authenticated malicious user sends manipulated HTTPS Content-Length header to the webserver.

5.4Orta
CVE-2025-3899
Schneider Electric Modicon Controllers M241/M251

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in Certificates page on Webserver that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in…

6.5Orta
CVE-2025-3898
Schneider Electric Modicon Controllers M241/M251; Schneider Electric Modicon Controllers M262

CWE-20: Improper Input Validation vulnerability exists that could cause Denial of Service when an authenticated malicious user sends HTTPS request containing invalid data type to the webserver.

7.5Yüksek
CVE-2025-2875
Schneider Electric Modicon Controllers M241 / M251; Schneider Electric Modicon Controllers M258 / LMC058

CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could cause a loss of confidentiality when an unauthenticated attacker manipulates controller’s webserver URL to access resources.