CVE-2025-25249Fortinet Multiple Products Heap-based Buffer Overflow Vulnerability

Fortinet FortiSwitchManager; Fortinet FortiOS; Siemens RUGGEDCOM APE1808 Yayım: (10 ay önce)

Aktif olarak istismar ediliyor — Fortinet Multiple Products Heap-based Buffer Overflow Vulnerability

CISA bu açığın gerçek saldırılarda kullanıldığını 09.09.2026 tarihinde doğruladı. ABD federal kurumları için düzeltme son tarihi: 12.09.2026.

Gerekli işlem: Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines. https://fortiguard.fortinet.com/psirt/FG-IR-25-084 ; BOD 26-04: https://www.cisa.gov/news-events/directives/bod-26-04-prioritizing-security-updates-based-risk ; Forensics Triage Requirements: https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk ; https://nvd.nist.gov/vuln/detail/CVE-2025-25249

Açıklama

A heap-based buffer overflow vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2.0 through 7.2.11, FortiOS 7.0.0 through 7.0.17, FortiOS 6.4 all versions, FortiSwitchManager 7.2.0 through 7.2.6, FortiSwitchManager 7.0.0 through 7.0.5 allows attacker to execute unauthorized code or commands via specially crafted packets

Zayıflık türü (CWE): CWE-122CWE-787

Veri: CVE.org, NVD, CISA KEV, FIRST EPSS, Ubuntu. Bilgiler kaynaktaki haliyle, İngilizce yayımlanır.

Etkilenen ürünler ve sürümler

ÜreticiÜrünSürümler
Fortinet FortiOS 7.6.0 – ≤ 7.6.2, 7.4.0 – ≤ 7.4.7, 7.2.4 – ≤ 7.2.11
fortinet fortisase 25.1.39
Fortinet FortiSwitchManager 7.2.2 – ≤ 7.2.5
Siemens RUGGEDCOM APE1808 0
siemens ruggedcom ape1808 firmware —

Kaynaklar ve yamalar

CPE eşleşmeleri (NVD) (9)

  • cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:* ≥ 6.4.0 < 7.0.18
  • cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:* ≥ 7.2.0 < 7.2.12
  • cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:* ≥ 7.4.0 < 7.4.9
  • cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:* ≥ 7.6.0 < 7.6.4
  • cpe:2.3:a:fortinet:fortiswitchmanager:*:*:*:*:*:*:*:* ≥ 7.0.0 < 7.0.6
  • cpe:2.3:a:fortinet:fortiswitchmanager:*:*:*:*:*:*:*:* ≥ 7.2.0 < 7.2.7
  • cpe:2.3:a:fortinet:fortisase:25.1.39:*:*:*:-:*:*:*
  • cpe:2.3:a:fortinet:fortisase:25.1.51:*:*:*:-:*:*:*
  • cpe:2.3:o:siemens:ruggedcom_ape1808_firmware:-:*:*:*:*:*:*:*