4.6Orta

CVE-2024-13176Timing side-channel in ECDSA signature computation

OpenSSL OpenSSL Yayım: (1 yıl önce)

Açıklama

Issue summary: A timing side-channel which could potentially allow recovering the private key exists in the ECDSA signature computation. Impact summary: A timing side-channel in ECDSA signature computations could allow recovering the private key by an attacker. However, measuring the timing would require either local access to the signing application or a very fast network connection with low latency. There is a timing signal of around 300 nanoseconds when the top word of the inverted ECDSA nonce value is zero. This can happen with significant probability only for some of the supported elliptic curves. In particular the NIST P-521 curve is affected. To be able to measure this leak, the attacker process must either be located in the same physical computer or must have a very fast network connection with low latency. For that reason the severity of this vulnerability is Low. The FIPS modules in 3.4, 3.3, 3.2, 3.1 and 3.0 are affected by this issue.

Zayıflık türü (CWE): CWE-385

Veri: CVE.org, NVD, CISA KEV, FIRST EPSS, Ubuntu. Bilgiler kaynaktaki haliyle, İngilizce yayımlanır.

Etkilenen ürünler ve sürümler

ÜreticiÜrünSürümler
debian debian linux 11.0
netapp 500f firmware —
netapp 8300 firmware —
netapp 8700 firmware —
netapp a250 firmware —
netapp a400 firmware —
netapp a700s firmware —
netapp active iq unified manager < 9.18
netapp bootstrap os —
netapp brocade fabric operating system —
netapp c250 firmware —
netapp c400 firmware —
netapp h300s firmware —
netapp h410c firmware —
netapp h410s firmware —
netapp h500s firmware —
netapp h610c firmware —
netapp h610s firmware —
netapp h615c firmware —
netapp h700s firmware —
netapp manageability software development kit —
netapp management services for element software and netapp hci —
netapp oncommand insight —
netapp oncommand workflow automation —
netapp ontap tools 9
netapp snapcenter ≤ 6.0.1
netapp snapmanager —
netapp solidfire & hci management node —
netapp solidfire & hci storage node —
OpenSSL OpenSSL 3.4.0 – < 3.4.1, 3.3.0 – < 3.3.3, 3.2.0 – < 3.2.4, 3.1.0 – < 3.1.8, 3.0.0 – < 3.0.16, 1.1.1 – < 1.1.1zb, 1.0.2 – < 1.0.2zl

Kaynaklar ve yamalar

CPE eşleşmeleri (NVD) (43)

  • cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:* ≥ 1.0.2 < 1.0.2zl
  • cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:* ≥ 1.1.1 < 1.1.1zb
  • cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:* ≥ 3.0.0 < 3.0.16
  • cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:* ≥ 3.1.0 < 3.1.8
  • cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:* ≥ 3.2.0 < 3.2.4
  • cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:* ≥ 3.3.0 < 3.3.3
  • cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:* ≥ 3.4.0 < 3.4.1
  • cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:linux:*:*
  • cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere:*:*
  • cpe:2.3:a:netapp:manageability_software_development_kit:-:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:management_services_for_element_software_and_netapp_hci:-:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:oncommand_workflow_automation:-:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:ontap_tools:9:*:*:*:*:vmware_vsphere:*:*
  • cpe:2.3:a:netapp:snapmanager:-:*:*:*:*:hyper-v:*:*
  • cpe:2.3:a:netapp:solidfire_\&_hci_management_node:-:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:solidfire_\&_hci_storage_node:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:brocade_fabric_operating_system:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:8700_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:a400_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:c400_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:8300_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:a250_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:500f_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:c250_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h300s_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h500s_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h700s_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h410s_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h410c_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h610c_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h610s_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h615c_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:active_iq_unified_manager:*:*:*:*:*:vmware_vsphere:*:* < 9.18
  • cpe:2.3:a:netapp:active_iq_unified_manager:*:*:*:*:*:windows:*:* < 9.18
  • cpe:2.3:a:netapp:oncommand_insight:-:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:snapcenter:*:*:*:*:*:*:*:* ≤ 6.0.1
  • cpe:2.3:a:netapp:snapcenter:6.1:-:*:*:*:*:*:*
  • cpe:2.3:a:netapp:snapcenter:6.1:p1:*:*:*:*:*:*
  • cpe:2.3:a:netapp:snapcenter:6.1:p2:*:*:*:*:*:*
  • cpe:2.3:o:netapp:a700s_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:bootstrap_os:-:*:*:*:*:*:*:*
  • cpe:2.3:o:debian:debian_linux:11.0:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:a700s_firmware:-:*:*:*:*:*:*:*