Vulnerabilidades de tenda ac7 firmware (CVE)

Registros CVE publicados para tenda ac7 firmware, los más recientes primero. Siga el producto para recibir un correo con cada nueva.

28 resultados
9.8Crítica
CVE-2026-51846
tenda ac7 firmware

In Tenda AC7 v15.03.06.44, the wanSpeed parameter of the route /goform/AdvSetMacMtuWan has a stack buffer overflow vulnerability that can lead to remote arbitrary code execution.

9.8Crítica
CVE-2026-51845
tenda ac7 firmware

Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the /goform/AdvSetMacMtuWan interface via the mac parameter.

9.8Crítica
CVE-2026-51844
tenda ac7 firmware

Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the /goform/AdvSetMacMtuWan interface via the cloneType parameter.

9.8Crítica
CVE-2026-51843
tenda ac7 firmware

Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the /goform/AdvSetMacMtuWan interface via the wanMTU parameter.

5.1Media
CVE-2026-24434

Tenda AC7 Web Interface Lacks CSRF Protections for Admin Actions

Shenzhen Tenda Technology Co., Ltd. Tenda AC7

Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior does not implement CSRF protections for administrative functions in the web management interface. The interface does not enforce anti-CSRF tokens or robust origin validation, which can allow an att…

6.8Media
CVE-2026-24427

Tenda AC7 Exposes Admin Credentials in Configuration Responses

Shenzhen Tenda Technology Co., Ltd. Tenda AC7

Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose sensitive information in web management responses. Administrative credentials, including the router and/or admin panel password, are included in plaintext within configuration response bodie…

5.1Media
CVE-2026-24426

Tenda AC7 Reflected XSS via Web Interface Output Encoding

Shenzhen Tenda Technology Co., Ltd. Tenda AC7

Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior contain an improper output encoding vulnerability in the web management interface. User-supplied input is reflected in HTTP responses without adequate escaping, allowing injection of arbitrary HTML…

8.8Alta
CVE-2025-11586

Tenda AC7 setNotUpgrade stack-based overflow

Tenda AC7

A vulnerability was determined in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/setNotUpgrade. This manipulation of the argument newVersion causes stack-based buffer overflow. The attack is possible to be carried out remotely. Th…

8.8Alta
CVE-2025-11528

Tenda AC7 saveAutoQos stack-based overflow

Tenda AC7

A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit…

8.8Alta
CVE-2025-11527

Tenda AC7 fast_setting_pppoe_set stack-based overflow

Tenda AC7

A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launc…

8.8Alta
CVE-2025-11526

Tenda AC7 WifiMacFilterSet stack-based overflow

Tenda AC7

A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing a manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remo…

8.8Alta
CVE-2025-11525

Tenda AC7 SetUpnpCfg stack-based overflow

Tenda AC7

A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been d…

1.1%EPSS
8.8Alta
CVE-2025-11524

Tenda AC7 SetDDNSCfg stack-based overflow

Tenda AC7

A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been …

1.1%EPSS
6.3Media
CVE-2025-11523

Tenda AC7 AdvSetLanip command injection

Tenda AC7

A vulnerability was detected in Tenda AC7 15.03.06.44. This vulnerability affects unknown code of the file /goform/AdvSetLanip. The manipulation of the argument lanIp results in command injection. It is possible to launch the attack remotely. The exploit is n…

3.4%EPSS
8.8Alta
CVE-2025-9023

Tenda AC7/AC18 SetLEDCfg formSetSchedLed buffer overflow

Tenda AC7; Tenda AC18

A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely.…

1.0%EPSS
8.8Alta
CVE-2025-5862

Tenda AC7 setPptpUserList formSetPPTPUserList buffer overflow

Tenda AC7

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated…

1.1%EPSS
8.8Alta
CVE-2025-5861

Tenda AC7 AdvSetLanip fromadvsetlanip buffer overflow

Tenda AC7

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be i…

8.1%EPSS
8.8Alta
CVE-2025-3346

Tenda AC7 SetPptpServerCfg formSetPPTPServer buffer overflow

Tenda AC7

A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptp_server_start_ip/pptp_server_end_ip leads to…

7.7%EPSS
9.8Crítica
CVE-2025-29135
tenda ac7 firmware

A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function.

1.1%EPSS
9.8Crítica
CVE-2025-29137
tenda ac7 firmware

Tenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set function, which can cause RCE.