8.8High KEV Used in ransomware

CVE-2017-0145Microsoft SMBv1 Remote Code Execution Vulnerability

Microsoft Corporation Windows SMB Published: (9 years ago)

Known exploited — Microsoft SMBv1 Remote Code Execution Vulnerability

CISA confirmed this vulnerability is used in real attacks on 10.02.2022. Remediation deadline for US federal agencies: 10.08.2022.

Required action: Apply updates per vendor instructions. https://nvd.nist.gov/vuln/detail/CVE-2017-0145

Description

The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to execute arbitrary code via crafted packets, aka "Windows SMB Remote Code Execution Vulnerability." This vulnerability is different from those described in CVE-2017-0143, CVE-2017-0144, CVE-2017-0146, and CVE-2017-0148.

Data: CVE.org, NVD, CISA KEV, FIRST EPSS, Ubuntu. Published as the sources state it, in English.

Affected products and versions

VendorProductVersions
microsoft server message block 1.0
Microsoft Corporation Windows SMB The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607
siemens acuson p300 firmware 13.02
siemens acuson p500 firmware va10
siemens acuson sc2000 firmware 4.0 – < 4.0e
siemens acuson x700 firmware 1.0
siemens syngo sc2000 firmware 4.0 – < 4.0e
siemens tissue preparation system firmware —
siemens versant kpcr molecular system firmware —
siemens versant kpcr sample prep firmware —

References and patches

CPE matches (NVD) (16)

  • cpe:2.3:a:microsoft:server_message_block:1.0:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:acuson_p300_firmware:13.02:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:acuson_p300_firmware:13.03:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:acuson_p300_firmware:13.20:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:acuson_p300_firmware:13.21:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:acuson_p500_firmware:va10:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:acuson_p500_firmware:vb10:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:acuson_sc2000_firmware:*:*:*:*:*:*:*:* ≥ 4.0 < 4.0e
  • cpe:2.3:o:siemens:acuson_sc2000_firmware:5.0a:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:acuson_x700_firmware:1.0:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:acuson_x700_firmware:1.1:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:syngo_sc2000_firmware:*:*:*:*:*:*:*:* ≥ 4.0 < 4.0e
  • cpe:2.3:o:siemens:syngo_sc2000_firmware:5.0a:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:tissue_preparation_system_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:versant_kpcr_molecular_system_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:versant_kpcr_sample_prep_firmware:*:*:*:*:*:*:*:*