Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP Schwachstellen (CVE)

Für Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP veröffentlichte CVE-Einträge, neueste zuerst. Folgen Sie, um bei neuen Einträgen eine E-Mail zu erhalten.

10 Ergebnisse
6.1Mittel
CVE-2026-63357
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly sanitize calculated signal data contained in imported calculated signal files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diag…

6.1Mittel
CVE-2026-63356
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly sanitize calculated signal names contained in imported CSV trace files before including them in error messages on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function rig…

6.1Mittel
CVE-2026-63355
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly sanitize signal names contained in imported CSV trace files before rendering them in selection menus on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read d…

9.6Kritisch
CVE-2026-63354
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly validate and sanitize visual marker data contained in imported CSV trace files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read dia…

9.6Kritisch
CVE-2026-63353
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly sanitize comment fields contained in imported trace files before rendering them on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into impo…

6.1Mittel
CVE-2026-63352
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly sanitize calculated signal data contained in imported CSV trace files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics”…

6.1Mittel
CVE-2026-63351
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly validate and sanitize visual properties of calculated signals contained in imported CSV trace files before rendering them on the Trace page. This could allow an attacker to social engineer an authorized user who holds the f…

9.6Kritisch
CVE-2026-63350
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly restrict executable content contained in imported trace files. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file…

9.6Kritisch
CVE-2025-40943
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly sanitize contents of trace files. This could allow an attacker to inject code through social engineering an authorized user, who has the function right "Read diagnostics", to import a specially crafted trace file. The ma…

5.3Mittel
CVE-2023-37482
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

The login functionality of the web server in affected devices does not normalize the response times of login attempts. An unauthenticated remote attacker could exploit this side-channel information to distinguish between valid and invalid usernames.