Siemens SIMATIC S7-1500 CPU 1517-3 PN Schwachstellen (CVE)

Für Siemens SIMATIC S7-1500 CPU 1517-3 PN veröffentlichte CVE-Einträge, neueste zuerst. Folgen Sie, um bei neuen Einträgen eine E-Mail zu erhalten.

12 Ergebnisse
6.1Mittel
CVE-2026-63357
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly sanitize calculated signal data contained in imported calculated signal files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diag…

6.1Mittel
CVE-2026-63356
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly sanitize calculated signal names contained in imported CSV trace files before including them in error messages on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function rig…

6.1Mittel
CVE-2026-63355
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly sanitize signal names contained in imported CSV trace files before rendering them in selection menus on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read d…

9.6Kritisch
CVE-2026-63354
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly validate and sanitize visual marker data contained in imported CSV trace files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read dia…

9.6Kritisch
CVE-2026-63353
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly sanitize comment fields contained in imported trace files before rendering them on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into impo…

6.1Mittel
CVE-2026-63352
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly sanitize calculated signal data contained in imported CSV trace files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics”…

6.1Mittel
CVE-2026-63351
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly validate and sanitize visual properties of calculated signals contained in imported CSV trace files before rendering them on the Trace page. This could allow an attacker to social engineer an authorized user who holds the f…

9.6Kritisch
CVE-2026-63350
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly restrict executable content contained in imported trace files. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file…

7.1Hoch
CVE-2026-25789
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly validate and sanitize filenames on the Firmware Update page. This could allow a remote attacker to social engineer the user into selecting the modified firmware file to be uploaded. This would result in malitcious JavaScript …

9.1Kritisch
CVE-2026-25787
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly validate and sanitize Technology Object (TO) name rendered on the "Motion Control Diagnostics" page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product,…

9.1Kritisch
CVE-2026-25786
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly validate and sanitize PLC/station name rendered on the "communication" parameters page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject m…

9.6Kritisch
CVE-2025-40943
Siemens SIMATIC Drive Controller CPU 1504D TF; Siemens SIMATIC Drive Controller CPU 1507D TF; Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN; Siemens SIMATIC ET 200SP CPU 1510SP-1 PN

Affected devices do not properly sanitize contents of trace files. This could allow an attacker to inject code through social engineering an authorized user, who has the function right "Read diagnostics", to import a specially crafted trace file. The ma…