Delta Electronics Delta UFC500 Schwachstellen (CVE)

Für Delta Electronics Delta UFC500 veröffentlichte CVE-Einträge, neueste zuerst. Folgen Sie, um bei neuen Einträgen eine E-Mail zu erhalten.

4 Ergebnisse
8.7Hoch
CVE-2026-22110

Missing authentication check on POST/PUT requests

Delta Electronics Delta UFC500

The web server does not check authentication on POST or PUT. An unauthenticated attacker can reboot the charger; by brute-forcing the configid, they can also set the service password and then change any setting.

8.7Hoch
CVE-2026-22105

Use of default password based on serial number

Delta Electronics Delta UFC500

Delta UFC500 charging stations derive the default credentials of the Service account from character positions of the device serial number. An unauthenticated attacker with adjacent network access can reconstruct the resulting password, or exhaust the keyspace…

8.4Hoch
CVE-2026-22109

Default WebUI passwords stored in plaintext

Delta Electronics Delta UFC500

The shipped WebUI template database retains the factory default passwords for all five account types in cleartext. Defaults are identical across devices and were unchanged on the tested unit.