cgm clininet Schwachstellen (CVE)

Für cgm clininet veröffentlichte CVE-Einträge, neueste zuerst. Folgen Sie, um bei neuen Einträgen eine E-Mail zu erhalten.

4 Ergebnisse
5.3Mittel
CVE-2025-58406

Lack of HTTP Response Headers

CGM CGM CLININET

The CGM CLININET application respond without essential security HTTP headers, exposing users to client‑side attacks such as clickjacking, MIME sniffing, unsafe caching, weak cross‑origin isolation, and missing transport security controls.

5.3Mittel
CVE-2025-58405

Lack of protection mechanisms against Clickjacking attacks

CGM CGM CLININET

The CGM CLININET application does not implement any mechanisms that prevent clickjacking attacks, neither HTTP security headers nor HTML-based frame‑busting protections were detected. As a result, an attacker can embed the application inside a maliciously cra…

7.1Hoch
CVE-2025-58402

Insecure Direct Object Reference Message ID

CGM CGM CLININET

The CGM CLININET application uses direct, sequential object identifiers "MessageID" without proper authorization checks. By modifying the parameter in the GET request, an attacker can access messages and attachments belonging to other users.

9.0Kritisch
CVE-2025-30042

Session generation possible with certificate number only

CGM CGM CLININET

The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alon…