3.5Niedrig

CVE-2024-2004Usage of disabled protocol

curl curl; Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP; Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP; Siemens SINEMA Remote Connect Client Veröffentlicht: (vor 2 Jahren)

Beschreibung

When a protocol selection parameter option disables all protocols without adding any then the default set of protocols would remain in the allowed set due to an error in the logic for removing protocols. The below command would perform a request to curl.se with a plaintext protocol which has been explicitly disabled. curl --proto -all,-http http://curl.se The flaw is only present if the set of selected protocols disables the entire set of available protocols, in itself a command with no practical use and therefore unlikely to be encountered in real situations. The curl security team has thus assessed this to be low severity bug.

Schwachstellentyp (CWE): CWE-115CWE-436

Daten: CVE.org, NVD, CISA KEV, FIRST EPSS, Ubuntu. Wiedergegeben wie in der Quelle, auf Englisch.

Betroffene Produkte und Versionen

HerstellerProduktVersionen
curl curl 8.6.0 – ≤ 8.6.0, 8.5.0 – ≤ 8.5.0, 8.4.0 – ≤ 8.4.0, 8.3.0 – ≤ 8.3.0, 8.2.1 – ≤ 8.2.1, 8.2.0 – ≤ 8.2.0, 8.1.2 – ≤ 8.1.2, 8.1.1 – ≤ 8.1.1, 8.1.0 – ≤ 8.1.0, 8.0.1 – ≤ 8.0.1, 8.0.0 – ≤ 8.0.0, 7.88.1 – ≤ 7.88.1, 7.88.0 – ≤ 7.88.0, 7.87.0 – ≤ 7.87.0, 7.86.0 – ≤ 7.86.0, 7.85.0 – ≤ 7.85.0
Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP V3.1.0 – < V3.1.5
Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP V3.1.0 – < V3.1.5
Siemens SINEC NMS < V3.0 SP1
Siemens SINEMA Remote Connect Client < V3.2 SP2
Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP V3.1.0 – < V3.1.5

Referenzen und Patches