9.8Kritisch KEV

CVE-2017-5689Intel Active Management Technology (AMT), Small Business Technology (SBT), and Standard Manageability Privilege Escalation Vulnerability

Intel Corporation Intel Active Mangement Technology, Intel Small Business Technology, Intel Standard Manageability Veröffentlicht: (vor 9 Jahren)

Bekannt ausgenutzt — Intel Active Management Technology (AMT), Small Business Technology (SBT), and Standard Manageability Privilege Escalation Vulnerability

CISA hat am 28.01.2022 bestätigt, dass diese Schwachstelle in echten Angriffen genutzt wird. Frist für US-Bundesbehörden: 28.07.2022.

Erforderliche Maßnahme: Apply updates per vendor instructions. https://nvd.nist.gov/vuln/detail/CVE-2017-5689

Beschreibung

An unprivileged network attacker could gain system privileges to provisioned Intel manageability SKUs: Intel Active Management Technology (AMT) and Intel Standard Manageability (ISM). An unprivileged local attacker could provision manageability features gaining unprivileged network or local system privileges on Intel manageability SKUs: Intel Active Management Technology (AMT), Intel Standard Manageability (ISM), and Intel Small Business Technology (SBT).

Schwachstellentyp (CWE): CWE-269

Daten: CVE.org, NVD, CISA KEV, FIRST EPSS, Ubuntu. Wiedergegeben wie in der Quelle, auf Englisch.

Betroffene Produkte und Versionen

HerstellerProduktVersionen
hpe proliant ml10 gen9 server firmware 5.0
intel active management technology firmware 6.0
Intel Corporation Intel Active Mangement Technology, Intel Small Business Technology, Intel Standard Manageability fixed in versions 6.2.61.3535, 7.1.91.3272, 8.1.71.3608, 9.1.41.3024, 10.0.55.3000, 11.0.25.3001, and 11.6.27.3264 and later
siemens simatic field pg m3 firmware < 6.2.61.3535
siemens simatic field pg m4 firmware < 18.01.06
siemens simatic field pg m5 firmware < 22.01.03
siemens simatic ipc427d firmware —
siemens simatic ipc427e firmware < 21.01.05
siemens simatic ipc477d firmware —
siemens simatic ipc477e firmware < 21.01.05
siemens simatic ipc547d firmware < 7.1.91.3272
siemens simatic ipc547e firmware < 9.1.41.3024
siemens simatic ipc547g firmware < 11.0.26.3000
siemens simatic ipc627c firmware < 6.2.61.3535
siemens simatic ipc627d firmware < 9.1.41.3024
siemens simatic ipc647c firmware < 6.2.61.3535
siemens simatic ipc647d firmware < 9.1.41.3024
siemens simatic ipc677c firmware < 6.2.61.3535
siemens simatic ipc677d firmware < 9.1.41.3024
siemens simatic ipc827c firmware < 6.2.61.3535
siemens simatic ipc827d firmware < 9.1.41.3024
siemens simatic ipc847c firmware < 6.2.61.3535
siemens simatic ipc847d firmware < 9.1.41.3024
siemens simatic itp1000 firmware < 9.1.41.3024
siemens simatic pcs 7 ipc427e firmware < 21.01.04
siemens simatic pcs 7 ipc477d firmware —
siemens simatic pcs 7 ipc547d firmware < 7.1.91.3272
siemens simatic pcs 7 ipc547e firmware < 9.1.41.3024
siemens simatic pcs 7 ipc547g firmware < 11.0.26.3000
siemens simatic pcs 7 ipc627c firmware < 6.2.61.3535
siemens simatic pcs 7 ipc647c firmware < 6.2.61.3535
siemens simatic pcs 7 ipc647d firmware < 9.1.41.3024
siemens simatic pcs 7 ipc677c firmware < 6.2.61.3535
siemens simatic pcs 7 ipc847c firmware < 6.2.61.3535
siemens simatic pcs 7 ipc847d firmware < 9.1.41.3024
siemens simotion p320-4 s firmware < 17.02.06.83.1
siemens sinumerik pcu50.5-p firmware < 6.2.61.3535

Referenzen und Patches

CPE-Treffer (NVD) (54)

  • cpe:2.3:o:hpe:proliant_ml10_gen9_server_firmware:5.0:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:* < 9.1.41.3024
  • cpe:2.3:o:siemens:simatic_ipc847d_firmware:*:*:*:*:*:*:*:* < 9.1.41.3024
  • cpe:2.3:o:siemens:simatic_ipc847c_firmware:*:*:*:*:*:*:*:* < 6.2.61.3535
  • cpe:2.3:o:siemens:simatic_ipc827d_firmware:*:*:*:*:*:*:*:* < 9.1.41.3024
  • cpe:2.3:o:siemens:simatic_ipc827c_firmware:*:*:*:*:*:*:*:* < 6.2.61.3535
  • cpe:2.3:o:siemens:simatic_ipc677d_firmware:*:*:*:*:*:*:*:* < 9.1.41.3024
  • cpe:2.3:o:siemens:simatic_ipc677c_firmware:*:*:*:*:*:*:*:* < 6.2.61.3535
  • cpe:2.3:o:siemens:simatic_ipc647d_firmware:*:*:*:*:*:*:*:* < 9.1.41.3024
  • cpe:2.3:o:siemens:simatic_ipc647c_firmware:*:*:*:*:*:*:*:* < 6.2.61.3535
  • cpe:2.3:o:siemens:simatic_ipc627d_firmware:*:*:*:*:*:*:*:* < 9.1.41.3024
  • cpe:2.3:o:siemens:simatic_ipc627c_firmware:*:*:*:*:*:*:*:* < 6.2.61.3535
  • cpe:2.3:o:siemens:simatic_ipc547g_firmware:*:*:*:*:*:*:*:* < 11.0.26.3000
  • cpe:2.3:o:siemens:simatic_ipc547e_firmware:*:*:*:*:*:*:*:* < 9.1.41.3024
  • cpe:2.3:o:siemens:simatic_ipc547d_firmware:*:*:*:*:*:*:*:* < 7.1.91.3272
  • cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:* < 21.01.05
  • cpe:2.3:o:siemens:simatic_ipc477d_firmware:-:*:*:*:-:*:*:*
  • cpe:2.3:o:siemens:simatic_ipc477d_firmware:-:*:*:*:pro:*:*:*
  • cpe:2.3:o:siemens:simatic_field_pg_m3_firmware:*:*:*:*:*:*:*:* < 6.2.61.3535
  • cpe:2.3:o:siemens:simatic_field_pg_m4_firmware:*:*:*:*:*:*:*:* < 18.01.06
  • cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:* < 22.01.03
  • cpe:2.3:o:siemens:simatic_ipc627d_firmware:*:*:*:*:*:*:*:* < 9.1.41.3024
  • cpe:2.3:o:siemens:simatic_ipc677d_firmware:*:*:*:*:*:*:*:* < 9.1.41.3024
  • cpe:2.3:o:siemens:simatic_pcs_7_ipc427e_firmware:*:*:*:*:*:*:*:* < 21.01.04
  • cpe:2.3:o:siemens:simatic_pcs_7_ipc547d_firmware:*:*:*:*:*:*:*:* < 7.1.91.3272
  • cpe:2.3:o:siemens:simatic_pcs_7_ipc547e_firmware:*:*:*:*:*:*:*:* < 9.1.41.3024
  • cpe:2.3:o:siemens:simatic_pcs_7_ipc547g_firmware:*:*:*:*:*:*:*:* < 11.0.26.3000
  • cpe:2.3:o:siemens:simatic_pcs_7_ipc627c_firmware:*:*:*:*:*:*:*:* < 6.2.61.3535
  • cpe:2.3:o:siemens:simatic_pcs_7_ipc677c_firmware:*:*:*:*:*:*:*:* < 6.2.61.3535
  • cpe:2.3:o:siemens:simatic_pcs_7_ipc647c_firmware:*:*:*:*:*:*:*:* < 6.2.61.3535
  • cpe:2.3:o:siemens:simatic_pcs_7_ipc647d_firmware:*:*:*:*:*:*:*:* < 9.1.41.3024
  • cpe:2.3:o:siemens:simatic_pcs_7_ipc847c_firmware:*:*:*:*:*:*:*:* < 6.2.61.3535
  • cpe:2.3:o:siemens:simatic_pcs_7_ipc847d_firmware:*:*:*:*:*:*:*:* < 9.1.41.3024
  • cpe:2.3:o:siemens:simatic_pcs_7_ipc427e_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:simatic_pcs_7_ipc547g_firmware:*:*:*:*:*:*:*:* < 11.0.26.3000
  • cpe:2.3:o:siemens:simatic_pcs_7_ipc477d_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:simatic_ipc427d_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:* < 21.01.05
  • cpe:2.3:o:siemens:simotion_p320-4_s_firmware:*:*:*:*:*:*:*:* < 17.02.06.83.1
  • cpe:2.3:o:siemens:sinumerik_pcu50.5-p_firmware:*:*:*:*:*:*:*:* < 6.2.61.3535
  • cpe:2.3:o:intel:active_management_technology_firmware:6.0:*:*:*:*:*:*:*
  • cpe:2.3:o:intel:active_management_technology_firmware:6.1:*:*:*:*:*:*:*
  • cpe:2.3:o:intel:active_management_technology_firmware:6.2:*:*:*:*:*:*:*
  • cpe:2.3:o:intel:active_management_technology_firmware:7.0:*:*:*:*:*:*:*
  • cpe:2.3:o:intel:active_management_technology_firmware:7.1:*:*:*:*:*:*:*
  • cpe:2.3:o:intel:active_management_technology_firmware:8.0:*:*:*:*:*:*:*
  • cpe:2.3:o:intel:active_management_technology_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:o:intel:active_management_technology_firmware:9.0:*:*:*:*:*:*:*
  • cpe:2.3:o:intel:active_management_technology_firmware:9.1:*:*:*:*:*:*:*
  • cpe:2.3:o:intel:active_management_technology_firmware:9.5:*:*:*:*:*:*:*
  • cpe:2.3:o:intel:active_management_technology_firmware:10.0:*:*:*:*:*:*:*
  • cpe:2.3:o:intel:active_management_technology_firmware:11.0:*:*:*:*:*:*:*
  • cpe:2.3:o:intel:active_management_technology_firmware:11.5:*:*:*:*:*:*:*
  • cpe:2.3:o:intel:active_management_technology_firmware:11.6:*:*:*:*:*:*:*